How to replace a Hunter Douglas battery wand

Two or three minutes, no tools, no ladder for most windows. The shade keeps its programming and re-pairs to your existing remote on its own.

Before you start

Make sure the wand is actually what failed. If the shade starts and stops partway, or the remote drives your other shades but not this one, a new wand changes nothing — the six-symptom check sorts that out in two minutes and will save you the money.

Have twelve new AA batteries ready, all the same brand, all new. See what batteries these take.

The sequence

1. Raise the shade fully. On a Vignette or a Provenance the fabric stacks into the headrail and will be in your way otherwise. On a wood blind, tilt the slats open instead.

2. Find the wand. It is a white plastic tube about fourteen inches long, clipped into a bracket at one end of the headrail. On Designer Roller and Banded shades it often mounts on its own bracket beside the rail rather than inside it. Our compatibility pages say where it sits on each line.

3. Slide it out along the rail. It moves lengthways, not downwards. If it will not budge you are probably pulling the wrong direction — on a Sonnette there is usually an end cap to release first.

4. Open the battery compartment and tip the old cells out. Keep the wand horizontal so they do not all shoot out at once.

5. Look at the orientation diagram printed on the tube. Do this even if you have done it before.

6. Load twelve new cells following that diagram exactly. All twelve, all new, all the same brand.

7. Slide the wand back into its bracket until it seats. You should feel it click.

8. Test it. The shade should respond to the remote within a few seconds. If it does not, take the wand out and check the cell directions before assuming anything is broken.

The two places people go wrong

One cell backwards. The cells are wired in series, so a single reversed battery blows the fuse in the end cap. That fuse is not serviceable and the wand is finished. This is the most common way a working wand becomes a dead one, and it usually happens to someone who has done the job before and stopped checking the diagram.

Mixing old cells with new. The string performs like its weakest cell, so eleven fresh batteries and one survivor from the old set gives you the runtime of the survivor. Replace all twelve together, every time.

If the old wand has leaked

White or green crust inside the tube means alkaline cells have vented and the residue has eaten the contacts. Do not just clean it and reload it. The corrosion keeps spreading through the spring and the end cap, and it will take your new batteries with it. That wand needs replacing — see which one fits your shade.

Wash your hands afterwards. The residue is caustic.

Do I need to re-program anything?

No. The shade's limits and its pairing live in the motor, not the wand. Swap the power source and everything else stays as it was.

If the shade genuinely has lost its remote pairing, that is a separate fault and re-pairing is free — it is one of the three symptoms on the check page that is not the wand.